archive-sg.com » SG » A » ALARMSUPPLY.COM.SG

Total: 60

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Alarm Supply Pte Ltd
    Ratchet adjustable stainless steel U bracket for 360 positioning All units offer IN OUT terminals Terminals accept 0 5 to 4 0mm 2 cable E2S MA121 Marine Grade IP67 Alarm Sounders General Introduction A heavy duty high output IP67 sealed sounder ideal for harsh environments with high ambient noise level Maximum output 126dB A 1 metre Nominal output 121dB A 1m 3dB Tone 2 45 alarm tones UKOOA PFEER compliant 3 stage alarm option Volume control Automatic synchronisation on multi sounder systems 350m effective range 1 kHz Voltages 24vdc 10 30vdc 48vdc 35 60vdc 24vac 115vac 230vac Other voltages available upon request DC versions may be used on 24vac 10 for single stage applications Positive stage switching DC version available Optional reverse polarity switching on DC units Fully programmable version with 4 stages available Third party tested to IP67 IP66 Enclosure material UL94V0 5VA rated FR ABS Colour available Grey RAL7038 Operating temperature 25 to 55 C Storage temperature 40 to 70 C Relative humidity 90 at 20 C Weight DC 2 50Kg AC 3 00Kg Large termination area 2 x M20 ISO cable gland entries with 1 blanking plug Ratchet adjustable stainless steel U bracket for 360 positioning All units offer IN OUT terminals Terminals accept 0 5 to 4 0mm 2 cable E2S BExTS110 BExDTS110 ATEX EEx Telephone Initiated Alarm Sounders General Introduction Maximum output 117dB A 1 metre Nominal output 110dB A 1m 3dB Tone 2 TS110D EEx d IIC T4 Tamb 50 to 55 C KEMA certified ATEX CENELEC FTZU approved Suitable for Zone 1 2 Gas groups IIC IIB IIA 32 alarm tones UKOOA PFEER compliant 100m effective range 1 kHz Voltages 115vac 230vac S110D IP67 Enclosure material Marine grade LM6 Aluminium Chromated powder coated finish good resistance to humidity and salt spray environments BExTS110D Horn High impact UL94 V0 5VA FR ABS BExDTS110D Horn Anti static High impact ABS Colour available Red RAL3000 Operating temperature 50 to 55 C Storage temperature 50 to 70 C Weight 3 20Kg KEMA Certificate number 99ATEX6312 The ring tone circuit senses the ringing voltage on the telephone line and switches the supply onto signal until the telephone is answered The sound can be continuous or follow the telephone ring selectable option Installation Features Very large termination area Dual M20 ISO cable gland entries supplied with one stopping plug Ratchet adjustable stainless steel U bracket for positive adjustment under harsh conditions IN OUT terminals Terminals accept 0 5 to 4 0mm 2 cables Telephone line ringing voltage switches power 115vac or 230vac to enable sounder to operate E2S BExL15 BExDL15 ATEX EEx 15 Watt Hazardous Area Loudspeakers General Introduction SPL 102dB 3dB 1w 1m Pink noise 113dB 3dB 15w Rated Power 1m L15D EEx d IIC T4 Tamb 50 to 55 C L15E EEx de IIC T4 Tamb 50 to 55 C KEMA certified ATEX CENELEC FTZU approved Suitable for Zone 1 2 Gas groups IIC IIB IIA Rated power 15 Watts RMS 70v line transformer version 15w 7 5w 3w 1w tappings z 336 67 Ohms 653 33 Ohms 1 6k Ohms 4 9k Ohms 100v line transformer version 15w 7 5w 3w 1w tappings z 666 87 Ohms 1 34k Ohms 3 34k Ohms 10k Ohms Impedance type 8 Ohm or 16 Ohm Dispersion 120 1kHz 32 4kHz Frequency range 400Hz to 8000Hz DC line monitoring 2 2uF Capacitor Transformer version 470uF Capacitor Impedance version L15D IP67 L15E IP66 Enclosure material Marine grade LM6 Aluminium Chromated powder coated finish good resistance to humidity and salt spray environments BExL15 Horn High impact UL94 V0 5VA FR ABS BExDL15 Horn Anti static High impact ABS Colour available Red RAL3000 Operating temperature 50 to 50 C Storage temperature 50 to 70 C Weight 70 100v line 3 45Kg Low impedance 3 10Kg KEMA Certificate number 99ATEX6312 Loudspeaker third party tested copy of report available on request Installation Features Very large termination area Dual M20 ISO cable gland entries supplied with one stopping plug Ratchet adjustable stainless steel U bracket for positive adjustment under harsh conditions IN OUT terminals Terminals accept 0 5 to 4 0mm 2 cables E2S BExL25 BExDL25 ATEX EEx 25 Watt Hazardous Area Loudspeakers General Introduction SPL 105dB 3dB 1w 1m Pink noise 117dB 3dB 25w Rated Power 1m L25D EEx d IIC T4 Tamb 50 to 55 C L25E EEx de IIC T4 Tamb 50 to 55 C KEMA certified ATEX CENELEC FTZU approved Suitable for Zone 1 2 Gas groups IIC IIB IIA Rated power 25 Watts RMS 70v line transformer version 25w 12 5w 6w 2w tappings z 196 Ohms 392 Ohms 816 67 Ohms 2 45k Ohms 100v line transformer version 25w 12 5w 6w 2w tappings z 400 Ohms 800 Ohms 1 67k Ohms 5k Ohms Impedance type 8 Ohm or 16 Ohm Dispersion 130 1kHz 32 4kHz Frequency range 300Hz to 8000Hz DC line monitoring 2 2uF Capacitor Transformer version 470uF Capacitor Impedance version L25D IP67 L25E IP66 Enclosure material Marine grade LM6 Aluminium Chromated powder coated finish good resistance to humidity and salt spray environments BExL25 Horn High impact UL94 V0 5VA FR ABS BExDL25 Horn Anti static High impact ABS Colour available Red RAL3000 Operating temperature 50 to 50 C Storage temperature 50 to 70 C Weight 70 100v line 3 95Kg Low impedance 3 56Kg KEMA Certificate number 99ATEX6312 Loudspeaker third party tested copy of report available on request Installation Features Very large termination area Dual M20 ISO cable gland entries supplied with one stopping plug Ratchet adjustable stainless steel U bracket for positive adjustment under harsh conditions IN OUT terminals Terminals accept 0 5 to 4 0mm 2 cables E2S ML15 Marine Grade IP67 15 Watt Loudspeaker General Introduction A heavy duty high output IP67 sealed loudspeaker ideal for harsh environments with high ambient noise levels SPL 108dB 3dB 1w 1m Pink noise 118dB 3dB 15w Rated Power 1m Rated power 15 Watts RMS 70v line transformer version 15w 7 5w 3w 1w tappings z 336 67 Ohms 653 33 Ohms 1 6k Ohms 4 9k Ohms 100v line transformer version 15w 7 5w 3w 1w tappings z 666 87 Ohms 1 34k Ohms 3 34k Ohms 10k Ohms Impedance type 8 Ohm or 16 Ohm Dispersion 120 1kHz 32 4kHz Frequency range 400Hz to 8000Hz DC line monitoring 2 2uF Capacitor Transformer type speaker 470uF Capacitor Impedance type speaker Transformer type fitted with thermal fuse Complies with BS5839 part 8 Third party tested to IP67 IP66 Enclosure material UL94V0 5VA rated FR ABS Colour available Grey RAL7038 Operating temperature 25 to 55 C Storage temperature 40 to 70 C Relative humidity 90 at 20 C Weight 70 100v line 2 60Kg Low impedance 2 20Kg Large termination area 2 x M20 ISO cable gland entries with 1 blanking plug Ratchet adjustable stainless steel U bracket for 360 positioning All units offer IN OUT terminals Terminals accept 0 5 to 4 0mm 2 cables E2S ML25 Marine Grade IP67 25 Watt Loudspeaker General Introduction A heavy duty high output IP67 sealed loudspeaker ideal for harsh environments with high ambient noise levels SPL 111dB 3dB 1w 1m Pink noise 121dB 3dB 15w Rated Power 1m Rated power 25 Watts RMS 70v line transformer version 25w 12 5w 6w 2w tappings z 196 Ohms 392 Ohms 816 67 Ohms 2 45k Ohms 100v line transformer version 25w 12 5w 6w 2w tappings z 400 Ohms 800 Ohms 1 67k Ohms 5k Ohms Impedance type 8 Ohm or 16 Ohm Dispersion 130 1kHz 30 4kHz Frequency range 300Hz to 8000Hz DC line monitoring 2 2uF Capacitor Transformer type speaker 470uF Capacitor Impedance type speaker Transformer type fitted with thermal fuse Complies with BS5839 part 8 Third party tested to IP67 IP66 Enclosure material UL94V0 5VA rated FR ABS Colour available Grey RAL7038 Operating temperature 25 to 55 C Storage temperature 40 to 70 C Relative humidity 90 at 20 C Weight 70 100v line 3 00Kg Low impedance 2 50Kg Large termination area 2 x M20 ISO cable gland entries with 1 blanking plug Ratchet adjustable stainless steel U bracket for 360 positioning All units offer IN OUT terminals Terminals accept 0 5 to 4 0mm 2 cables E2S BExA110 BExDA110 ATEX EEx Hazardous Area Voice Annunciation Unit General Introduction The sounder records stores and plays back user defined messages stored directly to non volatile memory without any intermediate analogue to digital conversion A single 16 second message may be recorded and played back with a choice of 1 of 10 user selectable alarm tones including silence to allow speech only option Nominal output 110dB A 1m 3dB Tone 5 A110D EEx d IIC T4 Tamb 50 to 55 C A110E EEx de IIC T4 Tamb 50 to 55 C KEMA certified ATEX CENELEC FTZU approved 10 alarm tones UKOOA PFEER compliant Edits automatically to message length Easy message creation with built in microphone Volume control 100m effective range 1kHz Voltages 24vdc 115vac 230vac DC versions has reverse polarity protection A110D IP67 A110E IP66 Enclosure material Marine grade LM6 Aluminium Chromated powder coated finish good resistance to humidity and salt spray environments BExA110 Horn High impact UL94V0 5VA FR ABS BExDA110 Horn Anti Static High impact ABS Operating temperature 50 to 55 C Storage temperature 50 to 70 C Large range of certified end of line resistors Weight DC 3 20Kg AC 3 40Kg KEMA Certificate number 99ATEX6312 Installation Features Very large termination area Dual M20 ISO cable gland entries supplied with one stopping plug Ratchet adjustable stainless steel U bracket for positive adjustment under harsh conditions IN and OUT terminals Terminals accept 0 5 to 4 0mm 2 cables Line monitoring Min 500 Ohm 2w 3k3 Ohm 0 5w resistor or diode within EExd enclosure dc versions E2S BExA120 BExDA120 ATEX EEx Hazardous Area Voice Annunciation Unit General Introduction The sounder records stores and plays back user defined messages stored directly to non volatile memory without any intermediate analogue to digital conversion A single 16 second message may be recorded and played back with a choice of 1 of 10 user selectable alarm tones including silence to allow speech only option Nominal output 113dB A 1m 3dB Tone 5 A120D EEx d IIC T4 Tamb 50 to 55 C A120E EEx de IIC T4 Tamb 50 to 55 C KEMA certified ATEX CENELEC FTZU approved 10 alarm tones UKOOA PFEER compliant Edits automatically to message length Easy message creation with built in microphone Volume control 100m effective range 1kHz Voltages 24vdc 115vac 230vac DC versions has reverse polarity protection A120D IP67 A120E IP66 Enclosure material Marine grade LM6 Aluminium Chromated powder coated finish good resistance to humidity and salt spray environments BExA120 Horn High impact UL94V0 5VA FR ABS BExDA120 Horn Anti Static High impact ABS Operating temperature 50 to 55 C Storage temperature 50 to 70 C Large range of certified end of line resistors Weight DC 3 20Kg AC 3 40Kg KEMA Certificate number 99ATEX6312 Installation Features Very large termination area Dual M20 ISO cable gland entries supplied with one stopping plug Ratchet adjustable stainless steel U bracket for positive adjustment under harsh conditions IN and OUT terminals Terminals accept 0 5 to 4 0mm 2 cables Line monitoring Min 500 Ohm 2w 3k3 Ohm 0 5w resistor or diode within EExd enclosure dc versions E2S MV112 Marine Grade IP67 Voice Annunciation Unit General Introduction A heavy duty high output IP67 sealed voice annunciation sounder ideal for harsh environments with high ambient The sounder records stores and plays back user defined messages stored directly to non volatile memory without any intermediate analogue to digital conversion A single 16 second or two 8 second messages may be recorded and played back with a choice of 1 of 10 user selectable alarm tones Maximum output 110dB A 1 metre Voice output approx 105dB A 1m 3dB Direct message storage on silicon 16 seconds of speech Very high voice reproduction quality moving coil loudspeaker 10 alarm tones including silence to allow speech only option UKOOA PFEER compliant Volume control tone duration control Message length 1 x 16 seconds or 2 x 8 seconds 100m effective range 1kHz Voltages 12vdc 9 15vdc 24vdc 18 30vdc 115vac 230vac Easy message creation with built in microphone Edits automatically to message length Third party tested to IP67 IP66 Enclosure material UL94V0 5VA rated FR ABS Colour available Grey RAL7038 Operating temperature 25 to 55 C Storage temperature 40 to 70 C Relative humidity 90 at 20 C Weight DC 2 50Kg AC 3 00Kg Large termination area 2 x M20 ISO cable gland entries with 1 blanking plug Ratchet adjustable stainless steel U bracket for 360 positioning Terminals accept 0 5 to 4 0mm 2 cables E2S A105N Appello P I R Voice Annunciation Unit General Introduction Record store a user defined 16 second voice message Message is repeated whilst P I R remains activated Maximum output 105dB A 1 metre Direct message storage on silicon 16 seconds of speech Very high voice reproduction quality moving coil loudspeaker Volume control P I R is in constant monitoring state replays message upon activation 32m effective range 1kHz Voltages 12vdc 9 15vdc 24vdc 18 30vdc 115vac 230vac Easy message creation with built in microphone Edits automatically to message length DC versions have reverse polarity diode protection IP55 can be increased to IP66 dust protected watertight with WR kit Tropicalisation available on request Enclosure material UL94V0 5VA rated FR ABS Colour available Red RAL3000 Grey or White Operating temperature 25 to 55 C Storage temperature 40 to 70 C Relative humidity 90 at 20 C Weight DC 0 75Kg AC 1 10Kg Cable gland knockouts in the rear of the unit Side M20 cable gland entry and IP55 stopping plug Unit can be mounted using external lugs or internal BESA compatible fixing positions All units offer IN and OUT terminals Terminals accept 0 5 to 2 5mm 2 cables E2S A105N Appello Speech Tone Voice Annunciation Unit General Introduction The sounder records stores and plays back user defined messages stored directly to non volatile memory without any intermediate analogue to digital conversion A single 16 second or two 8 second messages may be recorded and played back with a choice of 1 of 10 user selectable alarm tones Maximum output 105dB A 1 metre Direct message storage on silicon 16 seconds of speech Very high voice reproduction quality moving coil loudspeaker 10 alarm tones including silence to allow speech only option UKOOA PFEER compliant Volume control tone duration control Message length 1 x 16 seconds or 2 x 8 seconds 32m effective range 1kHz Voltages 12vdc 9 15vdc 24vdc 18 30vdc 115vac 230vac Easy message creation with built in microphone Edits automatically to message length DC versions have reverse polarity diode protection IP55 can be increased to IP66 dust protected watertight with WR kit Tropicalisation available on request Enclosure material UL94V0 5VA rated FR ABS Colour available Red RAL3000 Grey or White Operating temperature 25 to 55 C Storage temperature 40 to 70 C Relative humidity 90 at 20 C Weight DC 0 75Kg AC 1 00Kg Cable gland knockouts in the rear of the unit Side M20 cable gland entry and IP55 stopping plug Unit can be mounted using external lugs or internal BESA compatible fixing positions All units offer IN and OUT terminals Terminals accept 0 5 to 2 5mm 2 cables E2S A105N Appello Synchronised Voice Annunciation Unit General Introduction The sounder is primarily intended for use in fire alarm and evacuation systems It is fully synchronised with other units of the same type on the same circuit It offers a three stage alarm facility enabling three verbal messages to be linked with 1 of 10 different tones for the 1st stage and 1 of 3 tones for the 2nd 3rd stages Three volume levels and an adjustment potentiometer are provided The unit is preprogrammed with three standard messages 1 Please evacuate the building immediately 2 Alarm test take no action 3 Alarm test now complete or an alternative message of your choice can be stated when ordering Maximum output 105dB A 1 metre 3 sound levels selectable Direct message storage on silicon no degradation in reproduction or standby power required Very high voice reproduction quality moving coil loudspeaker 14 alarm tones 10 for 1st stage UKOOA PFEER compliant 3 stage alarm option 3 different messages Volume level settings Total message length 16 seconds 32m effective range 1kHz Voltages 24vdc 10 30vdc 115vac 230vac Automatic synchronisation on multi sounder systems Edits automatically to message length DC versions have reverse polarity diode protection IP55 can be increased to IP66 dust protected watertight with WR kit Tropicalisation available on request Enclosure material UL94V0 5VA rated FR ABS Colour available Red RAL3000 Grey or White Operating temperature 25 to 55 C Storage temperature 40 to 70 C Relative humidity 90 at 20 C Weight DC 0 75Kg AC 1 00Kg Cable gland knockouts in the rear of the unit Side M20 cable gland entry and IP55 stopping plug Unit can be mounted using external lugs or internal BESA compatible fixing positions All units offer IN and OUT terminals Terminals accept 0 5 to 2 5mm 2 cables E2S SON4 Sonora L E D Bulb Combination Alarm Sounder General Introduction A continuously rated compact combination sounder beacon ideal for fire and security applications Nominal output 100dB A 1m 3dB Tone 2 10 alarm tones 3 stage alarm option Volume control Automatic synchronisation on multi sounder systems 32m effective range 1kHz L E D beacon 5 x high intensity L E D 2Hz Bulb beacon 1 3 watt filament bulb 1Hz Wide range of voltages available Reverse polarity switching on DC units Reverse polarity diode protection on DC units IP55 can be increased to IP56 dust protected watertight with WR kit Tropicalisation available on request Enclosure material UL94V0 5VA rated FR ABS Colour available Red RAL3000 Grey or White Operating temperature 25 to 55 C Storage temperature 40 to 70 C Relative humidity 90 at 20 C Weight DC 0 30Kg AC 0 40Kg 4 x gland knockouts in side back Mounting via internal BESA compatible fixing positions AC units have external mounting lugs in addition to the above All units offer IN and OUT terminals Terminals accept 0 5 to 2 5mm 2 cables E2S SON4 Sonora Xenon Strobe Combination Alarm Sounder General Introduction A continuously rated compact combination sounder beacon ideal for fire and security applications Maximum output 104dB A 1 metre Nominal output 100dB A 1m 3dB Tone 2 32 alarm tones 3 stage alarm option Volume control 3 levels Automatic synchronisation on multi sounder systems 32m effective range 1 kHz Voltages 24vdc 24vac 115vac 230vac Other voltages available upon request Reverse polarity switching on DC units Reverse polarity diode protection on DC units IP55 can be increased to IP56 dust protected watertight with WR kit Tropicalisation available on request Enclosure material UL94V0 5VA rated FR ABS Colour available Red RAL3000 Grey or White Operating temperature 25 to 55 C Storage temperature 40 to 70 C Relative humidity 90 at 20 C Weight DC 0 30Kg AC 0 40Kg 4 x gland knockouts in side back Mounting via internal BESA compatible fixing positions Units also have external mounting lugs in addition to the above All units offer IN and OUT terminals Terminals accept 0 5 to 2 5mm 2 cables E2S MCA112 05 Combined Marine IP67 Sounder Beacon General Introduction A heavy duty high output IP67 sealed sounder beacon ideal for harsh environments with high ambient noise levels also requiring a visual indicator Maximum output 119dB A 1 metre Nominal output 112dB A 1m 3dB Tone 2 45 alarm tones UKOOA PFEER compliant 3 stage alarm option Volume control Automatic synchronisation on multi sounder systems 125m effective range 1 kHz Beacon 5 Joule 1Hz 5Ws Automatic synchronised flash or Flip Flop alternating mode 6 lens colours available Xenon tube mechanically secured against vibration shock Voltages 12vdc 24vdc 48vdc 24vac 115vac 230vac Other voltages available upon request 24vdc versions may be used on 24vac 10 for single stage applications Positive stage switching DC version available Reverse polarity switching on DC units Fully programmable version with 4 stages available Third party tested to IP67 IP66 Enclosure material UL94V0 5VA rated FR ABS Colour available Grey RAL7038 Operating temperature 25 to 55 C Storage temperature 40 to 70 C Relative humidity 90 at 20 C Weight DC 3 00Kg AC 3 50Kg Large termination area 2 x M20 ISO cable gland entries with 1 blanking plug Ratchet adjustable stainless steel U bracket for 360 positioning All units offer IN and OUT terminals Terminals accept 0 5 to 4 0mm 2 cables Sounder beacon may use same supply for simultaneous operation or seperate supplies for independent operation E2S MCV112 05 Marine Grade IP67 Voice Annunciation Beacon General Introduction A heavy duty high output IP67 sealed voice annunciator beacon ideal for harsh environments with high ambient noise levels also requiring a visual indicator Maximum output 110dB A 1 metre Voice output approx 105dB A 1m 3dB Direct message storage on silicon 16 seconds of speech Very high voice reproduction quality moving coil loudspeaker 10 alarm tones including silence to allow speech only option UKOOAV PFEER compliant Volume control tone duration control Message length 1 x 16 seconds or 2 x 8 seconds 100m effective range 1 kHz Voltages 12vdc 9 5vdc 24vdc 18 30vdc 115vac 230vac Easy message creation with built in microphone Edits automatically to message length Third party tested to IP67 IP66 Enclosure material UL94V0 5VA rated FR ABS Colour available Grey RAL7038 Operating temperature 25 to 55 C Storage temperature 40 to 70 C Relative humidity 90 at 20 C Weight DC 2 50Kg AC 3 00Kg Beacon 5 Joule 1Hz 5 Ws Automatic synchronised flash or Flip Flop alternating mode 6 lens colours available Xenon tube mechanically secured against vibration shock Large termination area 2 x M20 ISO Cable gland entries with 1 blanking plug Ratchet adjustable stainless steel U bracket for 360 positioning All units offer IN and OUT terminals Terminals accept 0 5 to 4 0mm 2 cables Sounder beacon may use same supply for simultaneous operation or seperate supplies for independent operation E2S MCL15 05 Marine Grade IP67 15w Loudspeaker Xenon Beacon General Introduction A heavy duty high output IP67 sealed loudspeaker beacon ideal for harsh environments with high ambient noise levels also requiring a visual indicator Third party tested to IP67 IP66 Enclosure material UL94V0 5VA rated FR ABS Colour available Grey RAL7038 Operating temperature 25 to 55 C Storage temperature 40 to 70 C Relative humidity 90 at 20 C Weight 70 100v line 2 60Kg Low inpedance 2 20Kg Large termination area 2 x M20 ISO Cable gland entries with 1 blanking plug Ratchet adjustable stainless steel U bracket for 360 positioning All units offer IN and OUT terminals Terminals accept 0 5 to 4 0mm 2 cables Loudspeaker SPL 108dB 3dB 1w 1m Pink noise 118dB 3dB 15w Rated Power 1m Rated power 15 Watts RMS 70v line transformer version 25w 12 5w 6w 2w tappings z 196 Ohms 392 Ohms 816 67 Ohms 2 45k Ohms 100v line transformer version 25w 12 5w 6w 2w tappings z 400 Ohms 800 Ohms 1 67k Ohms 5k Ohms Impedance type 8 Ohm or 16 Ohm Dispersion 120 1kHz 32 4kHz Frequency range 400Hz to 8000Hz DC line monitoring 2 2uF Capacitor Transformer type speaker 470uF Capacitor Impedance type speaker Transformer type fitted with thermal fuse Complies with BS5839 part 8 Beacon Beacon 5 Joule 1Hz 5 Ws Automatic synchronised flash or Flip Flop alternating mode 6 lens colours available Beacon voltage 12vdc 24vdc 48vdc 115vac 230vac DC versions have reverse polarity protection Xenon tube mechanically secured against vibration shock E2S BExCA110 05D BExDCA110 05D ATEX EEx Combined Voice Sounder Beacon General Introduction The sounder records stores and plays back user defined messages stored directly to non volatile memory without any intermediate analogue to digital conversion A single 16 second message may be recorded and played back with a choice of 1 of 10 user selectable alarm tones including silence to allow speech only CA110 05D EEx d IIB T4 Tamb 50 to 55 C KEMA certified ATEX CENELEC approved Voltages 24vdc 115vac 230vac CA110 05D IP67 Enclosure material Marine grade LM6 Aluminium Chromated powder coated finish good resistance to humidity and salt spray environments BExCA110 05D Horn High impact UL94 V0 5VA FR ABS BExDCA110 05D Horn Anti Static High impact ABS Colour available Red RAL3000 Operating temperature 50 to 55 C Storage temperature 50 to 70 C Large range of certified end of line resistors Weight DC 4 80Kg AC 5 00Kg KEMA Certificate number 01ATEX2223 Sounder Nominal output 110dB A 1m 3dB Tone 5 10 alarm tones including silence to allow speech only option UKOOA PFEER compliant Edits automatically to message length Easy message creation with built in microphone Volume control DC versions have reverse polarity protection 100m effective range 1 kHz Negative or positive remote switching Beacon 5 Joule 1Hz 60 FPM 5Ws Automatic synchronisation on multi beacon systems Beacons can be set to flip flop alternating mode with other units on multi beacon systems 6 lens colours available Amber Blue Clear Green Red Yellow Tube life emissions reduced to 70 after 8 million flashes Xenon tube mechanically secured against vibration shock Installation Features Large termination area Dual M20 ISO cable gland entries supplied with one stopping plug Ratchet adjustable stainless steel U bracket for positive adjustment under harsh conditions IN OUT terminals Terminals accept 0 5 to 4 0mm 2 cables Line monitoring Min 500 Ohm 2w or 3k3 Ohm 0 5w resistor or diode within EExd enclosure dc versions Sounder beacon may be connected from a single supply for simultaneous operation or from seperate supplies for independent operation E2S BExCS110 05D BExDCS110 05D ATEX EEx Combined Alarm Sounder Beacon General Introduction CS110 05D EEx d IIB T4 Tamb 50 to 55 C KEMA certified ATEX CENELEC approved Voltages 12vdc 24vdc 48vdc 115vac 230vac CS110 05D IP67 Enclosure material Marine grade LM6 Aluminium Chromated powder coated finish good resistance to humidity and salt spray environments BExCS110 05D Horn High impact UL94 V0 5VA FR ABS BExDCS110 05D Horn Anti Static High impact ABS Operating temperature 50 to 55 C Storage temperature 50 to 70 C Large range of certified end of line resistors Weight DC 4 80Kg AC 5 00Kg KEMA Certificate number 01ATEX2223 Sounder Maximum output 117dB A 1 metre Nominal output 110dB A 1m 3dB Tone 2 32 alarm tones UKOOA PFEER compliant 3 stage alarm Volume control Automatic synchronisation on multi sounder systems 100m effective range 1 kHz Negative or positive remote switching Beacon 5 Joule Xenon 1Hz 60 FPM 5Ws Automatic synchronisation on multi beacon systems Beacons can be set to flip flop alternating mode with other units on multi beacon systems 6 lens colours available Amber Blue Clear Green Red Yellow Tube life emissions reduced to 70 after 8 million flashes Xenon tube mechanically secured against vibration shock Installation Features Very large termination area Dual M20 ISO cable gland entries supplied with one stopping plug Ratchet adjustable stainless steel U bracket for positive adjustment under harsh conditions IN OUT terminals Terminals accept 0 5 to 4 0mm 2 cables Line monitoring Min 500 Ohm 2w or 3k3 Ohm 0 5w resistor or diode within EExd enclosure dc versions Sounder beacon may be connected from a single supply for simultaneous operation or from seperate supplies for independent operation E2S BExCL15 05D BExDCL15 05D ATEX EEx Combined Loudspeaker Beacon General Introduction CL15 05D EEx d IIB T4 Tamb 50 to 55 C KEMA certified ATEX CENELEC approved CS110 05D IP67 Enclosure material Marine grade LM6 Aluminium Chromated powder coated finish for harsh environments BExCL15 05D Horn High impact UL94 V0 5VA FR ABS BExDCL15 05D Horn Anti Static High impact ABS Colour available Red RAL3000 Operating temperature 50 to 55 C Storage temperature 50 to 70 C Large range of certified end of line resistors Weight 5 00Kg KEMA Certificate number 01ATEX2223 Loudspeaker SPL 102dB 3dB 1w 1m Pink noise 113dB 3dB 15w Rated Power 1m 70v line transformer 15w 7 5w 3w 1w tappings z 336 67 Ohms 653 33 Ohms 1 6k Ohms 4 9k Ohms 100v line transformer 15w 7 5w 3w 1w tappings z 666 87 Ohms 1 34k Ohms 3 34k Ohms 10k Ohms Impedance version 8 Ohm or 16 Ohm Dispersion 120 1kHz 32 4kHz Frequency range 400Hz to 8000Hz DC line monitoring 2 2uF Capacitor Transformer version 470uF Capacitor Impedance version Beacon 5 Joule 1Hz 60 FPM 5Ws Voltages 12vdc 24vdc 48vdc 115vac 230vac 6 lens colours Amber Blue Clear Green Red Yellow Automatic synchronisation on multi beacon systems Beacons can be set to flip flop alternating mode with other units on multi beacon systems Tube life emissions reduced to 70 after 8 million flashes Xenon tube mechanically secured against vibration shock Installation Features Large termination area Dual M20 ISO cable gland entries supplied with one stopping plug Ratchet adjustable stainless steel U bracket for positive adjustment under harsh conditions IN OUT terminals Terminals accept 0 5 to 4 0mm 2 cables Line monitoring Min 500 Ohm 2w or 3k3 Ohm 0 5w resistor or diode within EExd enclosure dc versions Loudspeaker component third party tested Gentex Photoelectric Smoke Alarm General Introduction Photoelectric Smoke Alarm For 120VAC and 220VAC Single or Multiple Tandem Station and Specialty Application Designed for single station tandem and specialty applications in homes commercial residential occupancies apartments hospitals and hotels in compliance with UL 217 UL1730 and NFPA 101 7 6 2 9 occupancies Exclusive patented 3 position test switch simulates 85 and 3 4 smoke conditions per NFPA 72 Chapter 7 UL 217 and UL 1730 standards 120VAC and 220VAC models available Patented three position test switch Includes 90 dB piezo solid state non latching horn Nominal 2 5 sensitivity 5 1 signal to noise ratio Solid State LED condition indicator Quick disconnect wiring harness Mounting hardware adapts to standard junction boxes Protective high air velocity gasket On site maintenance washing program 1 year warranty from date of purchase Temporal 3 Evacuation Sounding Device 7003 MEDC DB1 Range Sounders General Introduction This range of light weight flameproof Sounders has been designed with a high weatherproof rating to cope with the harsh environmental conditions found offshore and onshore in the oil gas and petrochemical industries New electronic circuitry allows the DB1P and DB1HP to be switched between two selectable tones by either reversing the supply polarity or connecting a second voltage supply The higher output DB1H and DB1HP are particularly suitable for noisy environments Zone 1 and Zone 2 use EExd IIB T3 ATEX approved Ex II 2G CENELEC approved BASEEFA certified UL Listed Class I Div 1 Groups C D GOST R certified Australian SAA certified IP66 Certified temperature 20 C to 70 C Up to 113 dBA output Available in marine grade alloy or stainless steel 6 or 27 output tones user selectable Telephone initiate option Tones can be selected remotely Tones comply with UKOOA PFEER guidelines Any two tones may be switched via the external voltage supply End of line resistor option MEDC DB3 Range Sounders General Introduction This range of light weight all GRP flameproof sounders is intended for use in potentially explosive gas and dust atmospheres and has been designed with high ingress protection to cope with the harsh environmental conditions found offshore and onshore in the oil gas and petrochemical industries The flamepaths flare and the body are manufactured completely from a UV stable glass reinforced polyester Stainless steel screws and sinter are incorporated thus ensuring a corrosion free product A tapered flamepath is used to overcome the problems of assembly of parallel spigot flamepaths An optional Exe terminal chamber is available An uncertified version is available for use in non explosive atmospheres Zone 1 Zone 2 and non Ex use EExde IIC T5 ATEX approved Ex II 2GD Optional Exe terminal chamber BASEEFA certified UL Listed for USA and Canada Hazardous locations Class I Div 2 Groups A D Class I Zones 1 2 AExd IIC T4 Ordinary locations Audible Signal Device GOST R K certified Chinese CQST certified Australian SAA certified IP66 and IP67 Certified temperature 55 C to 70 C All GRP corrosion free flamepaths Up to 118dBA output Integral volume control 27 tones user selectable Tones comply with UK00A PFEER guidelines Any two tones may be switched via the external voltage supply Tones may be programmed to customer specification d c version accepts any voltage between12V d c and 48V d c End of line resistor option Sounder Beacon Combination Unit available Depending on version MEDC DB3V Range Sounders General Introduction This range of light weight all GRP flameproof voice sounders is intended for use in potentially explosive gas and dust atmospheres and has been designed with high ingress protection to cope with the harsh environmental conditions found offshore and onshore in the oil gas and petrochemical industries The flamepaths flare and the body are manufactured completely from a UV stable glass reinforced polyester Stainless steel screws and sinter are incorporated thus ensuring a corrosion free product A tapered flamepath is used to overcome the problems of assembly of parallel spigot flamepaths This unit offers up to 20 seconds of speech which can be recorded via an integral microphone or an input from an external source The unit incorporates a variable delay allowing speech to be repeated at equal intervals of up to approximately 15 seconds In addition a mechanical bell sound version is available An optional Exe terminal chamber is available An uncertified version is available for use in non explosive atmospheres Zone 1 Zone 2 and non Ex use EExde IIC T5 ATEX approved Ex II 2GD Optional Exe terminal chamber BASEEFA certified GOST R K certified Chinese CQST certified IP66 and IP67 Certified temperature 55 C to 70 C All GRP corrosion free flamepaths Up to 110dBA output Integral volume control d c version accepts any voltage between 12V d c and 48V d c End of line resistor option Sounder Beacon Combination Unit available Bell recording version available Depending on version MEDC DB5 Range Sounders General Introduction This range of light weight intrinsically safe Sounders has been designed with a high weatherproof rating to cope with the harsh environmental conditions found offshore and onshore in the oil gas and petrochemical industries The unit is available in 2 models 12V and 24V Zone 0 Zone 1 and Zone 2 use EExia T4 ATEX approved Ex II 1G Ex 1 M1 BASEEFA certified FM Approved Class I Div 1 Groups A D CSA certified IP65 Certified temperature 20 C to 55 C Volume control as standard Up to 103 dB A 26 different sound outputs user selectable by internal switches Encapsulated electronics Second tone selectable using third wire MEDC DB6 Range Sounders General Introduction This explosionproof bell is available in two voltages The bell is manufactured from cast iron finished in epoxy paint Colour to customer s specification Zone 1 and Zone 2 use EExd IIB T5 ATEX approved Ex II 2G BASEEFA certified IP65 Certified temperature 20 C to 55 C 2 cable entries Proven track record Captive cover screws MEDC DB7 Range Sounders General Introduction This range of ruggedised intrinsically safe and weatherproof sounders intended for use in potentially explosive atmospheres has been designed with high ingress protection to cope with the harsh environmental conditions found offshore and onshore in the oil gas and petrochemical industries The unit is available in 12V and 24V versions and for gas groups IIB or IIC A lower cost uncertified version is available for use in non explosive atmospheres Zones 0 1 2 and safe area use EExia IIB IIC T4 ATEX approved Ex II 1G Weatherproof uncertified version BASEEFA certified GOST R certified IP66 IP67 Certified temperature 55 C to 70 C

    Original URL path: http://www.alarmsupply.com.sg/pro_sounders.html (2012-12-22)
    Open archived version from archive

  • Alarm Supply Pte Ltd
    C S E2S Eltek Firex Gentex GW KAC MEDC No Climb Radal Vimpex Listings by Category Please Select Beacons Detectors Door Holder Fire Control Panel Lighting Manual Call Points Sounders Sprinklers Status Lamps Testing Equipment There is no product listed

    Original URL path: http://www.alarmsupply.com.sg/pro_sprinklers.html (2012-12-22)
    Open archived version from archive

  • Alarm Supply Pte Ltd
    available Various lamp colours Lightweight Retained stainless steel cover screws Depending on version MEDC SM87 SL Range Status Lamps General Introduction Theses ranges of versatile status lights have been designed to suit various offshore and onshore applications Available as LED xenon filament and fluorescent beacons The SM87 SL range is manufactured in marine grade alloy and the XB11 SL in corrosion free GRP to provide a wide range of status lights to suit clients requirements All units can be supplied as 1 2 3 or 4 way Zone 1 and Zone 2 use EExd ATEX approved Ex II 2GD BASEEFA certified UL listed for USA and Canada Class I Div 1 2 Groups C D Class I Zone 1 AExd IIB T6 CSA certified GOST R K certified IP66 67 Certified temperature 55 C to 70 C LED xenon fluorescent filament Marine grade alloy or GRP Close coupled and pre wired to customer s requirements Model dependant MEDC XB11 SL Range Status Lamps General Introduction Theses ranges of versatile status lights have been designed to suit various offshore and onshore applications Available as LED xenon filament and fluorescent beacons The SM87 SL range is manufactured in marine grade alloy and the XB11 SL in corrosion free GRP to provide a wide range of status lights to suit clients requirements All units can be supplied as 1 2 3 or 4 way Zone 1 and Zone 2 use EExd ATEX approved Ex II 2GD BASEEFA certified UL listed for USA and Canada Class I Div 1 2 Groups C D Class I Zone 1 AExd IIB T6 CSA certified GOST R K certified IP66 67 Certified temperature 55 C to 70 C LED xenon fluorescent filament Marine grade alloy or GRP Close coupled and pre wired to customer s requirements Model

    Original URL path: http://www.alarmsupply.com.sg/pro_lamps.html (2012-12-22)
    Open archived version from archive

  • Alarm Supply Pte Ltd
    complete with 2 battery batons that fit inside the Solo poles and a charger which may be used in either a mains socket or in car Using CAT Cross Air Technology air is heated and blown across the cup which means the heat source is directed at the detector sensor not the plastic components or casing For battery conservation the tool does not begin to operate until the detector breaks the infra red beam in the cup No Climb Solo Aerosol General Introduction The Solo Aerosol is the result of an extensive two year research programme to produce the best most efficient and safest smoke aerosol The project within the government Teaching Company Scheme TCS brought together the test and service equipment skills of No Climb with the chemistry and particulate behaviour skills of a major London university An aerosol development scientist based at No Climb undertook research into aerosol products and detection devices concentrating on particle size characteristic and behaviour residue toxicity of product device response clearing times detector and component compatibility spray pattern Chemicals used in detector test equipment need to be compatible with the plastics from which detectors are manufactured This project included the most in depth plastic chemical compatibility tests ever conducted in this field and proved Solo aerosol to be chemically safe It also uncovered worrying deficiencies in currently available alternatives No Climb Solo CO Detector Duster Solo CO The only way to test a CO Fire detector is to introduce CO safely to the sensor from the outside demonstrating free flow and no blockages in the route from the atmosphere to the sensor available in a convenient aerosol canister format at a level which poses no threat to the user in normal use designed for use within the Solo 330 Dispenser therefore interchangeable with

    Original URL path: http://www.alarmsupply.com.sg/pro_testingeq.html (2012-12-22)
    Open archived version from archive

  • Alarm Supply Pte Ltd
    Listings by Category Please Select Beacons Detectors Door Holder Fire Control Panel Lighting Manual Call Points Sounders Sprinklers Status Lamps Testing Equipment Series 60 Heat Detector Ionisation Detector Optical Detector Series 65 Heat Detectors Ionisation Detector Optical Detector XPlorer XPlorer Heat Detector XPlorer Isolator XPlorer Manual Call Point MCP XPlorer Optical Smoke Detector XPlorer Output Unit XP95 Ionisation Smoke Monitor Isolator Manual Call Points Optical Smoke Monitor Temperature Monitor Orbis

    Original URL path: http://www.alarmsupply.com.sg/products_apollo.html (2012-12-22)
    Open archived version from archive

  • Alarm Supply Pte Ltd
    AlertAlight Xenon Strobe Beacon L101 Synchronised AlertAlight Xenon Strobe Beacon BExCBG05 05D Dual Xenon Beacons BExBG05D E Xenon Warning Beacons BExBG10D E Xenon Warning Beacons BExBG15D E Xenon Warning Beacons BExTBG05D Telephone Initiated Xenon Warning Beacons MB005 MB010 Marine IP67 Xenon Strobe Beacons MCB005 05 Marine IP67 Xenon Strobe Beacon Combination Units SON4 Sonora L E D Bulb Combination Alarm Sounder SON4 Sonora Xenon Strobe Combination Alarm Sounder MCA112 05 Combined Marine IP67 Sounder Beacon MCV112 05 Marine Grade IP67 Voice Annunciation Beacon MCL15 05 Marine Grade IP67 Loudspeaker Xenon Beacon BExCA110 05D BExDCA110 05D Combined Voice Sounder Beacon BExCS110 05D BExDCS110 05D Combined Alarm Sounder Beacon BExCL15 05D BExDCL15 05D Combined Loudspeaker Beacon Loudspeakers BExL15 BExDL15 Loudspeakers BExL25 BExDL25 Loudspeakers ML15 Marine Grade IP67 Loudspeaker ML25 Marine Grade IP67 Loudspeaker Sounders A140 Disaster Warning Alarm Sounder A100 AL100 AlertAlarm Alarm Sounder A100 AL100 Sontel Telephone Ringer Sounder A105N AL105N AlertAlarm Alarm Sounder A105N AL105N Sontel Telephone Ringer Sounder A105N IS Intrinsically Safe Alarm Sounder A112 AL112 AlertAlarm Alarm Sounder A121 AL121 AlertAlarm Alarm Sounder Bedhead Flush Mount Alarm Sounder SON2 Sonora Alarm Sounder SONF1 SONFL1 Sonora Alarm Sounder BExS110 BExDS110 Alarm Sounders BExS120 BExDS120 Alarm Sounders MA112 Marine Grade

    Original URL path: http://www.alarmsupply.com.sg/products_e2s.html (2012-12-22)
    Open archived version from archive

  • Alarm Supply Pte Ltd
    Eltek Firex Gentex GW KAC MEDC No Climb Radal Vimpex Listings by Category Please Select Beacons Detectors Door Holder Fire Control Panel Lighting Manual Call Points Sounders Sprinklers Status Lamps Testing Equipment Conventional Marine Precept Panel Addressable Discovery Panel Nexus

    Original URL path: http://www.alarmsupply.com.sg/products_ctrleq.html (2012-12-22)
    Open archived version from archive

  • Alarm Supply Pte Ltd
    Application Designed for single station tandem and specialty applications in homes commercial residential occupancies apartments hospitals and hotels in compliance with UL 217 UL1730 and NFPA 101 7 6 2 9 occupancies Exclusive patented 3 position test switch simulates 85 and 3 4 smoke conditions per NFPA 72 Chapter 7 UL 217 and UL 1730 standards 120VAC and 220VAC models available Patented three position test switch Includes 90 dB piezo

    Original URL path: http://www.alarmsupply.com.sg/pro_gentex.html (2012-12-22)
    Open archived version from archive